Part of the Auction CNC coordinate measuring machine in portal design
CNC coordinate measuring machine (CMM) in portal design Zeiss CMM CONTURA 7/7/6Trading#18262-1
Details
Product Type
Zeiss
Type
CMM CONTURA 7/7/6
Description
Supplement subject to change
Measuring volume X = 700 mm, Y = 700 mm, Z = 600 mm
The following specifications apply for:
S1: active sensors VAST XT gold, VAST XTR gold
S2: passive sensor VAST XXT with RDS
Temperature range 18 - 22 °C
Maximum temperature gradients 1.0 K/h; 1.5 K/d; 1.0 K/m
Maximum permissible length measurement error (MPE) according to ISO 10360-2:2009
MPE_E0 (3D) = (1.5 + L/350) µm for S1
MPE_E0 (3D) = (1.7 + L/350) µm for S2
Maximum permissible scanning deviation (MPE) according to ISO 10360-4:2000 within the maximum permissible scanning test time (MPT)
MPE_THP = 2.0 µm in MPT_tau = 40 s for S1
MPE_THP = 2.7 µm in MPT_tau = 50 s for S2
Single probe deviation form according to ISO 10360-5:2010
MPE_PFTU = 1.5 µm for S1
MPE_PFTU = 1.7 µm for S2
Form measurement deviation according to ISO 12181:2011 (VDI/VDE 2617 sheet 2.2)
MPE_RONt (MZCI) = 1.5 µm for S1
MPE_RONt (MZCI) = 1.7 µm for S2
Table height TH = 700 mm
prepared for tactile active and tactile passive sensors for Multi Application Sensor System (mass)
VAST navigator and/or VAST XXT measurement technologies (tactile active scanning and/or tactile passive scanning)
Note:
These measurement technologies only achieve optimal performance when using accessories from ZEISS
PC-based Integrated Scanning Control (ISC) through internal control C99m
Glass-ceramic scales in all 3 axes
Integrated passive vibration damping
AirSaver technology to reduce air consumption
Front protection with control panel holder
A Zeiss technician dismantled the gantry and the entire machine was properly secured, packed, transported and stored
. We will be happy to send you a copy of the service report and the as-is inspection on request.
Measuring volume X = 700 mm, Y = 700 mm, Z = 600 mm
The following specifications apply for:
S1: active sensors VAST XT gold, VAST XTR gold
S2: passive sensor VAST XXT with RDS
Temperature range 18 - 22 °C
Maximum temperature gradients 1.0 K/h; 1.5 K/d; 1.0 K/m
Maximum permissible length measurement error (MPE) according to ISO 10360-2:2009
MPE_E0 (3D) = (1.5 + L/350) µm for S1
MPE_E0 (3D) = (1.7 + L/350) µm for S2
Maximum permissible scanning deviation (MPE) according to ISO 10360-4:2000 within the maximum permissible scanning test time (MPT)
MPE_THP = 2.0 µm in MPT_tau = 40 s for S1
MPE_THP = 2.7 µm in MPT_tau = 50 s for S2
Single probe deviation form according to ISO 10360-5:2010
MPE_PFTU = 1.5 µm for S1
MPE_PFTU = 1.7 µm for S2
Form measurement deviation according to ISO 12181:2011 (VDI/VDE 2617 sheet 2.2)
MPE_RONt (MZCI) = 1.5 µm for S1
MPE_RONt (MZCI) = 1.7 µm for S2
Table height TH = 700 mm
prepared for tactile active and tactile passive sensors for Multi Application Sensor System (mass)
VAST navigator and/or VAST XXT measurement technologies (tactile active scanning and/or tactile passive scanning)
Note:
These measurement technologies only achieve optimal performance when using accessories from ZEISS
PC-based Integrated Scanning Control (ISC) through internal control C99m
Glass-ceramic scales in all 3 axes
Integrated passive vibration damping
AirSaver technology to reduce air consumption
Front protection with control panel holder
A Zeiss technician dismantled the gantry and the entire machine was properly secured, packed, transported and stored
. We will be happy to send you a copy of the service report and the as-is inspection on request.
Location
- Industriestr., 24558 Henstedt-Ulzburg
Dates
Inspection
Viewing is possible by prior arrangement, please contact us briefly.
Contact Person
Parts of this page have been machine translated. The German original text applies.
Your individual consultation
Our experts will be happy to advise you. Call +49 40 355059-132 or write to service@netbid.com